Application Note
Serial Communication Controller (SCC
™
): SDLC Mode of Operation
11-5
Figure 2. Typical SDLC Receive Sequence with Receive Interrupts on all Received
Characters or Special Condition
RxCLK
Rx Data
Opening Flag
Data 81H
Data 42H
Data 0FFH
Data 42H
CRC 0E013H
Closing Flag
Note 9
/INT
Note 3
➘
Note 3
➘
Note 4
➘
Note 6
➘
Note 1 Note 5
➘
Note 7
➘
Note 8
➘
Note 9
➘
/SYNC
➘
Note 2