SCC/ESCC
User Manual
UM010903-0515 Register Descriptions
140
Underrun selected, the SCC sends an abort and Flag on underrun if the TX Underrun/EOM latch
has been reset.
Write Register 0 in the Z85X30
D7 D6 D5 D4 D3 D2 D1 D0
0 0 0 Register 0
0 0 1 Register 1
0 1 0 Register 2
0 1 1 Register 3
1 0 0 Register 4
1 0 1 Register 5
1 1 0 Register 6
1 1 1 Register 7
0 0 0 Register 8
0 0 1 Register 9
0 1 0 Register 10
0 1 1 Register 11
1 0 0 Register 12
1 0 1 Register 13
1 1 0 Register 14
1 1 1 Register 15
With Point High Command
*
*
g( p )
0 0 0 Null Code
0 0 1 Point High
0 1 0 Reset Ext/Status Interrupts
0 1 1 Send Abort (SDLC)
1 0 0 Enable Int on Next Rx Character
1 0 1 Reset Tx Int Pending
1 1 0 Error Reset
1 1 1 Reset Highest IUS
0 0 Null Code
0 1 Reset Rx CRC Checker
1 0 Reset Tx CRC Generator
1 1 Reset Tx Underrun/EOM Latch